Keyword Index

Object: DWCircuit

Method: addDevice

Adds a device to the circuit (i.e. places it on the diagram)

DWDevice addDevice(type);

DWDevice addDevice(type, posX, posY);

DWDevice addDevice(type, posX, posY, orient);

DWDevice addDevice(type, posX, posY, orient, page);

DWDevice addDevice(type, posX, posY, orient, page, hitTest);

DWDevice addDevice(libName, partName);

DWDevice addDevice(libName, partName, posX, posY);

DWDevice addDevice(libName, partName, posX, posY, orient);

DWDevice addDevice(libName, partName, posX, posY, orient, page);

DWDevice addDevice(libName, partName, posX, posY, orient, page, hitTest);

Parameters
Name Expected Type Description
partName String The part name of the desired item in the library
orient char A character specifying the orientation of the device, see below, defaults to E
libName String A string uniquely identifying a currently open library, usually the file name
page integer The destination page for the device in the range 1..#pages, defaults to 1
hitTest boolean Specifies whether the pin connection points on the device should be checked for connection to existing signals in the circuit, defaults to false.
type DWType A DWType object representing the part type to be instantiated
posY integer The Y position of the top left corner of the device, in 1/1000", defaults to 0. If this circuit is to be viewed and edited later, then this value should be a multiple of the grid spacing of 70 units.
posX integer The X position of the top left corner of the device, in 1/1000", defaults to 0. If this circuit is to be viewed and edited later, then this value should be a multiple of the grid spacing of 70 units.

Returns:

Returns a DWDevice object representing the new device

Remarks:

The first style of call is intended for making invisible circuits and will place the device in the center of the page in standard orientation. The other parameters allow the position and orientation of the device to be specified.

The orientation parameter can be one of the following: E=East, e=East-flipped, W=West, w=West-flipped, N=North, n=North-flipped, S=South, s=South-flipped.

It is the caller's responsibility to ensure that the X and Y coordinates provided adhere to the grid requirements of the circuit. This normally means that they must be a multiple of 70.

Method: addGraphic

Adds a graphic item to the circuit (i.e. places it on the diagram)

void addGraphic(pic, posX, posY);

void addGraphic(pic, posX, posY, page);

Parameters
Name Expected Type Description
pic DWPic A DWPic object containing the graphic items to be added to the schematic. If the picture object contains exactly one primitive element (e.g. a line) then it is added as is. If there are more than one element, they are added as a group.
page integer The destination page for the graphic in the range 1..#pages, defaults to 1 \
posY integer The Y position of the top left corner of the graphic, in 1/1000".
posX integer The X position of the top left corner of the graphic, in 1/1000".

Returns:

None

Method: addPage

Adds one more page to the circuit

DWPage addPage();

DWPage addPage(visible);

Parameters
Name Expected Type Description
visible bool Specifies whether the new page should be opened (made visible). Defaults to false if not specified

Returns:

DWPage object representing the new page

Method: addPortConn

Adds a device to the circuit (i.e. places it on the diagram) so that it is positioned adjacent to and connects to the given existing pin in the circuit. This is primarily intended for automatically adding port connector devices to a subcircuit but nothing restricts the device type to being a port connector.

DWDevice addPortConn(type, pin);

Parameters
Name Expected Type Description
pin DWPin A DWPin object representing the pin to connect to
type DWType A DWType object representing the part type to be instantiated

Returns:

Returns a DWDevice object representing the new device

Remarks:

The device being placed is assumed to have one visible pin and is rotated and positioned so that this pin connects to the given pin.

Method: addSignal

Adds a signal to the circuit.

DWSignal addSignal();

DWSignal addSignal(page);

Parameters
Name Expected Type Description
page integer The destination page for the signal in the range 1..#pages, defaults to 1

Returns:

Returns a DWSignal object representing the new signal

Remarks:

The signal will initially be invisible until pin connections and lines are attached to it.

It is not normally necessary to use this call to create a signal. Every time a device is added, signals are already created for each pin, so simply connecting pins together will result in signal structures existing as needed. This method can be used if a signal with no connections is needed or if data order makes it simpler to create and name signals before connecting devices to them.

Property: allInstances

Gets a string array containing the instance locators for all possible physical instances of this object

SPArray allInstances();

Property: attributeList

Gets or sets the attribute list (i.e. the collection of all attribute values) associated with this object.

SPArray attributeList();

attributeList = SPArray

Returns:

Returns or accepts an SPArray of DWAttribute objects

Method: bundles

Retrieves an array of bundles (represented by (DWSignal) objects) for the circuit with various filtering options.

The parameter options for this call are identical to DWCircuit.signals except that only bundles are returned

Property: changed

Gets or sets the "changed" status of the circuit. If the circuit is marked as changed, a close by the user will prompt for a save, otherwise it will just close immediately.

bool changed();

changed = bool

Method: clear

Deletes the selected objects in the circuit. This is equivalent to the Clear menu command.

void clear();

Method: close

Closes the design associated with this circuit with or without prompting the user.

void close();

void close(force);

Parameters
Name Expected Type Description
force bool true to close the design without saving or prompting the user.

Remarks:

If this method is called with no argument or with force=false, this is equivalent to selecting the Close Design command. With force=true, the design is closed immediately with no prompt and no save.

Method: copy

Copies the selected objects in the circuit to the system clipboard or to a given circuit.

void copy();

void copy(destCct);

Parameters
Name Expected Type Description
destCct DWCircuit The destination circuit for the copy. The circuit is cleared (i.e. all existing objects deleted) before the copy. If this argument is provided, the system clipboard is not affected by this operation. If the argument is not given, this method is equivalent to the Copy menu command.

Method: cut

Copies the selected objects in the circuit to the system clipboard or to a given circuit, then deletes the selected objects from the source circuit.

void cut();

void cut(destCct);

Parameters
Name Expected Type Description
destCct DWCircuit The destination circuit for the copy. The circuit is cleared (i.e. all existing objects deleted) before the copy. If this argument is provided, the system clipboard is not affected by this operation. If the argument is not given, this method is equivalent to the Cut menu command.

Method: defineAttribute

Defines or modifies the definition of an attribute field in the design associated with this circuit

int defineAttribute(fieldName, options);

Parameters
Name Expected Type Description
fieldName String Name of the field to define, must meet the rules for a valid name
options String String containing letters corresponding to field options (see below) and an optional length limit. This value cannot be empty and must define at least one of the allowed object types

Returns:

Returns the internal field number (1..N) for the defined or modified field, or 0 if any error

Remarks:

This table defines the available options.
LetterDescription
AAllow carriage return
CDefined for design
DDefined for devices
FFixed field (cannot be removed once defined, usually only used for fields required for internal operation)
GGroup with Name field
LLocation fixed, cannot be repositioned by the user
MTemporary field, value is not saved to file
NOnly valid name characters allowed in value (this is not enforced in this version)
PDefined for pins
RRotate with the device
SDefined for signals
UOnly valid numeric characters allowed in value (this is not enforced in this version)
VMake value visible by default (other settings in the program affect visibility and may override this setting)
WShow field name with value by default
XValue fixed, cannot be edited by the user
YPrimary field, will be displayed when "Primary Only" is selected

The flag letters may be optionally followed by an integer specifying the maximum value length. This length is not enforced in the program and is only used to determine the type of box displayed when prompting for a value.

NOTE: This method can be called on any circuit or subcircuit in a design, but the attribute definitions apply to the entire design

EXAMPLE: The string
DY32
will specify a primary field, valid for devices, with maximum value length of 32

Method: deselectAll

Deselects all objects on the given page of this circuit, as if the user had clicked the mouse in an unused area of the diagram.

void deselectAll();

void deselectAll(pageNum);

Parameters
Name Expected Type Description
pageNum int The page number (1..N) containing the objects to deselect. If this is not specified, then the current page is used, or, if no current page, page 1 is used.

Property: design

Gets the design containing this circuit, may be itself if this is a top-level circuit. Read-only

DWCircuit design();

Method: devices

Retrieves an array of device objects for the circuit with various filtering options.

SPArray = devices

SPArray = devices(tokenList);

SPArray = devices(fieldName, value, ...);

SPArray = devices(fieldName, regExp, ...);

SPArray = devices(options, fieldName, value, ...);

SPArray = devices(options, fieldName, regExp, ...);

SPArray = devices(options, restrict, fieldName, value, ...);

SPArray = devices(options, restrict, fieldName, regExp, ...);

SPArray = devices(options, restrict, scope, fieldName, value, ...);

SPArray = devices(options, restrict, scope, fieldName, regExp, ...);

SPArray = devices(options);

SPArray = devices(options, restrict);

SPArray = devices(options, restrict, scope);

Parameters
Name Expected Type Description
scope int This is used in hierarchical designs to determine how much of the hierarchy is extracted. This can be exactly one of the following values:
  • 3 HIER_SCOPE_DESIGN
  • 4 HIER_SCOPE_CIRCUIT
  • 5 HIER_SCOPE_HEREDOWN
  • 6 HIER_SCOPE_TOPCIRCUIT
  • 7 HIER_SCOPE_OPEN.
If this parameter is not specified, the specified circuit level is scanned.
regExp RegExp A regular expression that will be applied to the preceding attribute field. If the expression matches, the device is included in the list.
value String The value of the preceding attribute field that must be matched exactly for the device to be included in the list.
fieldName String The name of an attribute field. The following parameter can be a string value, which must be exactly equal for the device to be included, or can be a regular expression. Any number of fieldName/value or fieldName/regExp pairs can be specified.
options int This is a set of flags that allows you to filter the list to include/exclude various categories of devices. This argument can be any OR of the following values:
  • 1 OPTION_SELECTED_ONLY
  • 2 OPTION_INCL_PSEUDO_DEVS
  • 4 OPTION_INCL_DEFS
  • 8 OPTION_EXCL_INSTANCES
  • 128 OPTION_INCL_PARENT_DEV
  • 512 OPTION_IGNORE_MODE
If this parameter is not given, you will get all non-pseudo-devices in the given circuit.
tokenList String A comma-separated list of token numbers of devices
restrict int This selects a bit in the Restrict attribute field that will be used to exclude certain devices. This can be exactly one of the following:
  • -1 RESTRICT_NONE
  • 0 RESTRICT_REPORT
  • 1 RESTRICT_PACKAGE
  • 2 RESTRICT_OPEN.
If this parameter is not included, the Restrict attribute is ignored.

Returns:

Returns an SPArray object containing a list of all devices(DWDevice) specified by the option parameters.

Remarks:

Returns an array with one element for each device requested. All devices on all pages of this circuit are included. If you only want a specific page, use DWPage.devices.

If no parameters are specified, you will get a list of all the devices on all pages of the given circuit, excluding pseudo-devices such as bus breakouts and page connectors.

A variety of different combinations of parameters can be passed, and the meaning of each is determined by the data type of the parameter. If the first one, two or three parameters are integers, then they are interpreted as the options, restrict and scope parameters, respectively. Once any non-integer (normally a string) parameter is encountered, this is assumed to be an attribute value filter, as follows

Any remaining parameters are taken as attribute field name/value or field name/regular expression pairs. Any devices matching the given values or patterns will be included in the list.

Note that this array is not updated automatically. If you perform other operations that add or delete devices, this array will be invalid and should be retrieved again. This can cause the program to bomb if misused!

Example:

cct = currentCircuit();
devs = cct.devices();     // All the non-pseudo-devices in the circuit
devs = cct.devices("Part", "RES", "Name", /R1.+/);   // All devices with Part field equal to "RES" and Name matching the given expression
devs = cct.devices(1);        // All selected devices in the circuit

Property: fileAppVersion

An integer indicating the program version that created the associated design file. Read only.

int fileAppVersion();

Remarks:

NOTE: The returned value is a 20-bit binary integer which can be interpreted as 5 hex digits.

For example, version 4.2.1 will be 0x42100. Version 4.5b1 will be 0x450b1, etc. The various parts can be extracted using standard bit operations, e.g. the major version number can be extracted using major = (v & 0xf0000) >> 16

Property: fileDir

The directory path of the file associated with this circuit, i.e. the name of the directory containing the file. Read only.

String fileDir();

Property: fileFormatVersion

An integer indicating the format version of the associated design file. Read only.

int fileFormatVersion();

Remarks:

NOTE: This number specifies the format of the file and is changed only when non backward-compatible changes are made to the format. It is not necessarily changed when the program version number changes. The format number was changed to 6 for EMTPWorks 4.0 as a result of a number of file format changes to accommodate Unicode strings, and other changes.

Property: fileName

The name of the file associated with this circuit, i.e. the file name without any directory path. Read only.

String fileName();

Property: filePath

The full directory path and file name of the file associated with this circuit. Read only.

String filePath();

Method: findByLocator

Searches the design containing this circuit for an object (circuit, device, signal or pin) that matches the given locator string.

object findByLocator(loc);

object findByLocator(loc, rel);

Parameters
Name Expected Type Description
loc String The locator string
rel boolean true to search relative to this circuit, false to search relative to the root of the design containing this circuit. false by default

Returns:

Returns a DWDevice, DWSignal, DWCircuit or DWPin object representing the object found or null if no match.

Remarks:

A locator string has encoded in it the type of object it specifies, so this method will return that type of object. You can use the "objType" method to determine what type of object you have received.

Method: findObjectByName

Searches given circuit for an ActiveX object with the given name. This gives direct access to the objects properties and methods.

object findObjectByName(name);

Parameters
Name Expected Type Description
name String The name of the object

Returns:

Returns a direct interface to the object or null if no match.

Remarks:

If there are multiple objects with the same name, the first one found will be returned.

Property: frame

Gets the bouding frame for the given page of this circuit

DWRect = frame

DWRect = frame(pageNum);

DWRect = frame(pageNum, selectedOnly);

Parameters
Name Expected Type Description
selectedOnly Boolean True to frame only the selected objects in the circuit, defaults to false.
pageNum int The page number to retrieve the frame for. Defaults to 1 if not supplied.

Method: getAttribute

Gets an attribute value from this object

String getAttribute(fieldName);

Parameters
Name Expected Type Description
fieldName String The name of the field to retrieve

Returns:

Returns a string representing the value of the specified attribute field. This string will be empty (zero length) if the field does not exist.

Method: getAttributeDefinition

Returns the internal field number, option flags and maximum value length for the field

String getAttributeDefinition(fieldName);

Parameters
Name Expected Type Description
fieldName String Name of the field to query

Returns:

Returns the option string, described below. Returns an empty string if there is no definition for the given name

Remarks:

See defineAttribute for the flag letters used to specify field options. The returned option string consists of:

NOTE: This method can be called on any circuit or subcircuit in a design, but the attribute definitions apply to the entire design

Method: getAttributeFieldNames

Returns an array of field names matching the given option flags

SPArray getAttributeFieldNames(options);

Parameters
Name Expected Type Description
options String Option flags. This can contain any combination of the flag characters given below. Any flag in this value must match the corresponding bit in the field definition to select the field

Returns:

Returns an array of names

Remarks:

This table defines the available options.
FlagDescription
CDefined for circuit (design)
DDefined for devices
PDefined for pins
SDefined for signals
YPrimary field, will be displayed when "Primary Only" is selected

Method: getAttributeVis

Gets the visibility of an attribute on this object

bool getAttributeVis(fieldName);

Parameters
Name Expected Type Description
fieldName String The name of the field to retrieve

Returns:

Returns true if the field is displayed on the schematic, false otherwise

Method: getCircuitLocatorByName

Returns the locator of a circuit given a hierarchical name.

object getCircuitLocatorByName(name);

Parameters
Name Expected Type Description
name String The name to search for

Returns:

Returns a string containing the locator name of the circuit, or null if not found.

Remarks:

NOTES:

Method: getDefaultDeviceName

Returns the next unused name having the given prefix. The prefix can be either given explicitly, derived from a given device or type or obtained from the design's default settings

String getDefaultDeviceName();

String getDefaultDeviceName(prefix);

String getDefaultDeviceName(device);

String getDefaultDeviceName(type);

Parameters
Name Expected Type Description
prefix String The prefix to use in generating the name
device DWDevice A device object which will be checked for a prefix attribute
type DWType A tyype object that will be checked for prefix attributes

Remarks:

In all cases, the default settings are the final resort, i.e. if no prefix is provided or if the given object has no prefix attributes, the settings from the design or default application settings will be used

Method: getDefaultSignalName

Returns the next unused name having the given prefix. The prefix can be either given explicitlyor obtained from the design's default settings

String getDefaultSignalName();

String getDefaultSignalName(prefix);

String getDefaultSignalName(doBus3);

Parameters
Name Expected Type Description
doBus3 bool pass true to use the default prefix for 3-phase bus signals, otherwise the default prefix for general signals is used
prefix String The prefix to use in generating the name

Remarks:

In all cases, the default settings are the final resort, i.e. if no prefix is provided the settings from the design or default application settings will be used

Method: getDeviceLocatorByName

Returns the locator of a device given a hierarchical name.

object getDeviceLocatorByName(name);

Parameters
Name Expected Type Description
name String The name to search for

Returns:

Returns a string containing the locator of the device, or null if not found.

Remarks:

NOTES:

Method: getLineStyle

Creates a new line style or gets an existing line style associated with this design

DWLineStyle = getLineStyle(name, detach);

Parameters
Name Expected Type Description
detach bool If true, a clone of the specified line style is created but with a new name and GUID assigned so that changes will not affect other objects using this style. If false, this object will refer directly to the identified style definition and changes will affect any other users of this style. Defaults to false
name String The name or GUID of the desired line style. If this is not specified, a new, empty line style is created

Method: getNameByLocator

Returns the hierarchical name of the object that matches the given locator string.

object getNameByLocator(loc);

Parameters
Name Expected Type Description
loc String The locator string

Returns:

Returns a string containing the hierarchical name of the object, or null if not found.

Remarks:

NOTES:

Property: getProperties

Gets a properties object associated with this object.

Property: getProperty

Gets a named property associated with this object.

Method: getSignalLocatorByName

Returns the locator of a signal given a hierarchical name.

object getSignalLocatorByName(name);

Parameters
Name Expected Type Description
name String The name to search for

Returns:

Returns a string containing the locator of the signal, or null if not found.

Remarks:

NOTES:

Property: instanceHierName

Gets or sets the selected physical instance of the circuit using its hierarchical name to identify it

String instanceHierName();

instanceHierName = String

Remarks:

The instance locator string identifies the currently selected unique physical instance of an object within a hierarchical circuit structure. Setting the instance locator does not change the locator of the definition object, it only selects one of the possible physical instances that can be represented by this definition. If the given instance locator is not valid for this definition, it is ignored. If it is valid and is different than the current selected instance and if the instance is in a displayed circuit, the display will be updated to reflect the change.

Property: instanceLocator

Gets or sets the selected physical instance of the circuit using its locator to identify it

String instanceLocator();

instanceLocator = String

Remarks:

The instance locator string identifies the currently selected unique physical instance of this object within a hierarchical circuit structure. Setting the instance locator does not change the locator of the definition object, it only selects one of the possible physical instances that can be represented by this definition. If the given instance locator is not valid for this definition, it is ignored. If it is valid and is different than the current selected instance and if the instance is in a displayed circuit, the display will be updated to reflect the change.

Property: isLocked

Gets the "locked" status of the circuit, i.e. whether it can be opened by the user.

bool isLocked();

Remarks:

This property is read-only

Property: isOpen

Returns true if this circuit is open (i.e. it is still in memory and any window is open), false if it has been closed

bool isOpen();

Property: isPhysical

Gets or sets the "physical" hierarchy mode of the design

bool isPhysical();

isPhysical = bool

Property: isReadOnly

Gets or sets the "read-only" status of the circuit

bool isReadOnly();

isReadOnly = bool

Method: locateDevices

Retrieves an array of device objects for the circuit with various filtering options.

SPArray = locateDevices

SPArray = locateDevices(baseLocator);

SPArray = locateDevices(baseLocator, fieldName, value, ...);

SPArray = locateDevices(baseLocator, fieldName, regExp, ...);

SPArray = locateDevices(baseLocator, options, fieldName, value, ...);

SPArray = locateDevices(baseLocator, options, fieldName, regExp, ...);

SPArray = locateDevices(baseLocator, options);

Parameters
Name Expected Type Description
regExp RegExp A regular expression that will be applied to the preceding attribute field. If the expression matches, the device is included in the list.
value String The value of the preceding attribute field that must be matched exactly for the device to be included in the list.
fieldName String The name of an attribute field. The following parameter can be a string value, which must be exactly equal for the device to be included, or can be a regular expression. Any number of fieldName/value or fieldName/regExp pairs can be specified.
baseLocator String The locator string of the circuit to be scanned, or its parent device. If this is empty or not specified, this circuit is scanned and the returned locators will be relative to this circuit. Note that this parameter serves two purposes, it locates the base circuit to use for the scan, and it is also the prefix for all returned locators. If it is absolute (starts with a "/" character) then the scan and the returned locators are relative to the top level of the design regardless of whether this circuit object is the top level.
options int This is a set of flags that allows you to filter the list to include/exclude various categories of devices. This argument can be any OR of the following values:
  • 1 OPTION_SELECTED_ONLY
  • 2 OPTION_INCL_PSEUDO_DEVS
  • 4 OPTION_INCL_DEFS
  • 8 OPTION_EXCL_INSTANCES
  • 128 OPTION_INCL_PARENT_DEV
  • 512 OPTION_IGNORE_MODE
If this parameter is not given, you will get all non-pseudo-devices in the given circuit.

Returns:

Returns an SPArray object containing the locators of all devices matching the option parameters.

Remarks:

Returns an array with one element for each device requested. All devices on all pages of this circuit are included.

If no parameters are specified, you will get a list of all the devices on all pages of the given circuit, excluding pseudo-devices such as bus breakouts and page connectors.

A variety of different combinations of parameters can be passed, and the meaning of each is determined by the data type of the parameter. If the first one, two or three parameters are integers, then they are interpreted as the options and restrict parameters, respectively. Once any non-integer (normally a string) parameter is encountered, this is assumed to be an attribute value filter, as follows

Any remaining parameters are taken as attribute field name/value or field name/regular expression pairs. Any devices matching the given values or patterns will be included in the list.

Example:

cct = currentCircuit();
devs = cct.locateDevices();           // All the non-pseudo-devices in the current circuit
devs = cct.locateDevices(baseLoc);    // All the non-pseudo-devices in the circuit specified by the given locator
devs = cct.locateDevices("", "Part", "RES", "Name", /R1.+/);  // All devices with Part field equal to "RES" and Name matching the given expression
devs = cct.locateDevices("", 1);   // All selected devices in the circuit

Property: locator

Gets the locator string of the circuit

String locator();

Remarks:

The locator string identifies an object within a hierarchical circuit structure and provides a unique way of identifying this object despite duplicate or non-existant names.

Property: name

Gets the name of the circuit, i.e. the name of the file it is saved in.

String name();

Remarks:

This is a read-only property.

Property: objType

Returns a string with the name of this object class "DWCircuit".

String = objType

Method: open

Opens a window on the circuit, or just brings an existing window to the front if it is already open.

void open();

Property: pages

Retrieves an array of page objects for the circuit

SPArray = pages

Returns:

Returns an SPArray object containing a list of all pages in this circuit

Remarks:

Returns an array with one element for each page in this circuit, whether or not the pages are open. Note that this array is not updated automatically. If you perform other operations that add or delete pages, this array will be invalid and should be retrieved again.

Property: parentDevice

Gets the parent device of this circuit, if it is a subcircuit, or null if this is a top-level circuit. Read-only.

DWDevice parentDevice();

Returns:

DWDevice object representing the parent device of this subcircuit

Remarks:

The value of this property will depend on the hierarchy mode of the design and may depend on whether the subcircuit is open for editing. If the design is in physical hierarchy mode and the current circuit is a physical instance circuit (i.e. not a definition circuit), this will be the parent device of the given physical subcircuit instance. In pure mode designs, this property has no conceptual meaning (since a given subcircuit may have many parents), but is set to a specific value to track the order in which the user has opened subcircuits.

Property: parentType

Gets the parent device type of this circuit, if it is a subcircuit, or null if this is a top-level circuit. Read-only.

DWType parentType();

Returns:

DWType object representing the parent type of this subcircuit

Method: paste

Copies the contents of the system clipboard or a given source circuit to this circuit.

void paste();

void paste(srcCct);

void paste(srcCct, dstPage);

void paste(srcCct, dstPage, posX, posY);

void paste(srcCct, dstPage, posX, posY, orientation);

void paste(srcCct, dstPage, posX, posY, orientation, hitTest);

void paste(srcCct, dstPage, posX, posY, orientation, hitTest, replace);

void paste(srcCct, dstPage, posX, posY, orientation, hitTest, replace, returnOptions);

Parameters
Name Expected Type Description
srcCct DWCircuit The source circuit for the paste. If the argument is not given or is null, this method is equivalent to the Paste menu command and all other arguments are ignored.
returnOptions int Allows the caller to request that the method return a list of the objects created. The possible values are 0 => no return value (the default), 1 => return an array of the devices created, 2 => return an array of the signals created, 3 => return an array containing both devices and signals (these may be intermixed in any order). Note that if hit testing is enabled, the number of signals returned may not be equal to the number in the source circuit as only newly-created signals are returned
orientation char A character specifying the orientation of the paste, one of the following: E=East, e=East-flipped, W=West, w=West-flipped, N=North, n=North-flipped, S=South, s=South-flipped., defaults to E
dstPage int The destination page for the paste. If this is <= 0, the current page is used.
hitTest boolean Specifies whether the loose connection points on the pasted circuit should be checked for connection to existing signals in the destination circuit, defaults to false.
replace boolean When true, indicates that the pasted objects are replacing objects that were just removed from the same circuit, e.g. for a move or rotate operation. In this case, the replaced objects retain their original token numbers, making Undo operations more consistent. If this is false, all objects are assigned new token numbers. Defaults to false.
posY int The horizontal position for the paste, in circuit coordinates
posX int The horizontal position for the paste, in circuit coordinates. If these are not specified, the objects are pasted at 0,0, the center of the page.

Method: pins

Retrieves an array of pin objects for the circuit with various filtering options.

SPArray = pins

SPArray = pins(fieldName, value, ...);

SPArray = pins(fieldName, regExp, ...);

SPArray = pins(options, fieldName, value, ...);

SPArray = pins(options, fieldName, regExp, ...);

SPArray = pins(options, restrict, fieldName, value, ...);

SPArray = pins(options, restrict, fieldName, regExp, ...);

SPArray = pins(options, restrict, scope, fieldName, value, ...);

SPArray = pins(options, restrict, scope, fieldName, regExp, ...);

SPArray = pins(options);

SPArray = pins(options, restrict);

SPArray = pins(options, restrict, scope);

Parameters
Name Expected Type Description
scope int This is used in hierarchical designs to determine how much of the hierarchy is extracted. This can be exactly one of the following values:
  • 3 HIER_SCOPE_DESIGN
  • 4 HIER_SCOPE_CIRCUIT
  • 5 HIER_SCOPE_HEREDOWN
  • 6 HIER_SCOPE_TOPCIRCUIT
  • 7 HIER_SCOPE_OPEN.
If this parameter is not specified, the specified circuit level is scanned.
regExp RegExp A regular expression that will be applied to the preceding attribute field. If the expression matches, the device is included in the list.
value String The value of the preceding attribute field that must be matched exactly for the device to be included in the list.
fieldName String The name of an attribute field. The following parameter can be a string value, which must be exactly equal for the device to be included, or can be a regular expression. Any number of fieldName/value or fieldName/regExp pairs can be specified.
options int This is a set of flags that allows you to filter the list to include/exclude various categories of devices. This argument can be any OR of the following values:
  • 1 OPTION_SELECTED_ONLY
  • 2 OPTION_INCL_PSEUDO_DEVS
  • 4 OPTION_INCL_DEFS
  • 8 OPTION_EXCL_INSTANCES
  • 128 OPTION_INCL_PARENT_DEV
  • 512 OPTION_IGNORE_MODE
If this parameter is not given, you will get all non-pseudo-devices in the given circuit.
restrict int This selects a bit in the Restrict attribute field that will be used to exclude certain devices. This can be exactly one of the following:
  • -1 RESTRICT_NONE
  • 0 RESTRICT_REPORT
  • 1 RESTRICT_PACKAGE
  • 2 RESTRICT_OPEN.
If this parameter is not included, the Restrict attribute is ignored.

Returns:

Returns an SPArray object containing a list of all pins (DWPin) specified by the option parameters.

Remarks:

Returns an array with one element for each pin requested. All pins on all devices on all pages of this circuit are included.

If no parameters are specified, you will get a list of all the pins on all pages of the given circuit, excluding pins on pseudo-devices such as bus breakouts and page connectors.

A variety of different combinations of parameters can be passed, and the meaning of each is determined by the data type of the parameter. If the first one, two or three parameters are integers, then they are interpreted as the options, restrict and scope parameters, respectively. Once any non-integer (normally a string) parameter is encountered, this is assumed to be an attribute value filter, as follows

Any remaining parameters are taken as attribute field name/value or field name/regular expression pairs. Any pins matching the given values or patterns will be included in the list.

Note that this array is not updated automatically. If you perform other operations that add or delete devices, this array will be invalid and should be retrieved again. This can cause the program to bomb if misused!

Example:

cct = currentCircuit();
ps = cct.pins();      // All the pins on non-pseudo-devices in the circuit
ps = cct.pins("PinFunc", "OUTFUNC");   // All pins with PinFunc field equal to "OUTFUNC"
ps = cct.pins(1);     // All selected pins in the circuit

Property: readOnly

Returns true if the circuit is marked "read only". Note that this status primarily affects the user interface and does not prevent script methods from making changes to the circuit.

bool = readOnly

Method: redo

Performs a redo operation, exactly as if the Redo menu command was selected by the user.

void redo();

Property: redraw

Force a redraw of the circuit window

void redraw();

void redraw(redrawAll);

Parameters
Name Expected Type Description
redrawAll bool If true, all open windows on this circuit will be redrawn, if false only the current (topmost) circuit window is redrawn. Default is false

Method: save

Saves the design associated with this circuit, as if the user had selected the Save command.

bool save();

Returns:

Returns a boolean value true if the save succeeded, false if it failed or was cancelled by the user in response to a prompt.

Method: saveAs

Saves the design associated with this circuit to a file. The file can be specified directly or by prompting the user.

bool saveAs();

bool saveAs(filePath);

Parameters
Name Expected Type Description
filePath String The directory path and file name of the desired destination file. An absolute path should be provided since there are no guarantees what the current directory will be at the time of the save.

Returns:

Returns a boolean value true if the save succeeded, false if it failed or was cancelled by the user in response to a prompt.

Remarks:

When called with no argument, this method is equivalent to the user selecting the "Save As" file menu item. When called with a file path, the design is saved to the given path as if the user had done as Save As to that location.

Method: saveCopy

Saves the design associated with this circuit to a specified file. The design's name, file path, modified dates and save status are not affected by this call so the design is not associated with the saved file in any way.

bool saveCopy(filePath);

Parameters
Name Expected Type Description
filePath String The directory path and file name of the desired destination file. An absolute path should be provided since there are no guarantees what the current directory will be at the time of the save.

Returns:

Returns a boolean value true if the save succeeded, false if it failed or was cancelled by the user in response to a prompt.

Property: saved

Gets the "saved" status of the design, i.e. if the design was read from or has been saved to a file. Read only.

bool saved();

Remarks:

This property says only whether the design has ever been saved to a file, it doesn't tell you whether the design has been modified since it was last saved. See changed

Method: select

Makes this circuit current by bringing one of its windows to the front

void select();

Method: selectAll

Deselects all objects on the given page of this circuit, as if the user had clicked the mouse in an unused area of the diagram.

void selectAll();

void selectAll(pageNum);

Parameters
Name Expected Type Description
pageNum int The page number (1..N) containing the objects to select. If this is not specified, then the current page is used, or, if no current page, page 1 is used.

Method: selectedObjectsProperties

Gets or sets the merged values of all selected objects in this circuit.

DWSchemaObject = selectedObjectsProperties

selectedObjectsProperties = DWSchemaObject

Method: setAttribute

Sets an attribute value in this object

void setAttribute(fieldName, value);

void setAttribute(fieldName, value, visibility);

Parameters
Name Expected Type Description
value String The new value for the specified field
fieldName String The name of the field to set
visibility int How to set visibility of resulting attribute text. 0 (false) = hide, 1 (true) = show, 2 = use default setting in design's attribute table, -1 = leave current visibility If this parameter is not supplied, 2 is assumed.

Returns:

Null.

Remarks:

If the given field name is not defined in the design's attribute table, it is added automatically. It is preferable to ensure that any fields used are already defined in the target design to make sure the settings are appropriate.

Method: setAttributeDefaultVis

Sets the default visibility for the named attribute field for objects created in this design.

void setAttributeDefaultVis(fieldName, vis);

Parameters
Name Expected Type Description
fieldName String The name of the field to set
vis int The desired new visibility setting. This can be false (or zero) meaning never visible, true (or 1) meaning always visible, or 2 meaning use the object's own default setting.

Property: setProperty

Sets a named property associated with this object.

Method: showByLocator

Searches the design containing this circuit for an object (circuit, device, signal or pin) that matches the given locator string.

void showByLocator(loc, flags);

void showByLocator(loc);

Parameters
Name Expected Type Description
loc String The locator string
flags int any combination of: cFBLShow = 1; cFBLSelect = 2; cFBLDeselectOthers = 4; If not specified, assumes all flags on

Method: signals

Retrieves an array of signal (DWSignal) objects for the circuit with various filtering options.

SPArray = signals

SPArray = signals(fieldName, value, ...);

SPArray = signals(fieldName, regExp, ...);

SPArray = signals(options, fieldName, value, ...);

SPArray = signals(options, fieldName, regExp, ...);

SPArray = signals(options, scope, fieldName, value, ...);

SPArray = signals(options, scope, fieldName, regExp, ...);

SPArray = signals(options);

SPArray = signals(options, scope);

Parameters
Name Expected Type Description
scope int This is used in hierarchical designs to determine how much of the hierarchy is extracted. This can be exactly one of the following values:
  • 3 HIER_SCOPE_DESIGN
  • 4 HIER_SCOPE_CIRCUIT
  • 5 HIER_SCOPE_HEREDOWN
  • 6 HIER_SCOPE_TOPCIRCUIT
  • 7 HIER_SCOPE_OPEN.
If this parameter is not specified, the specified circuit level is scanned.
regExp RegExp A regular expression that will be applied to the preceding attribute field. If the expression matches, the signal is included in the list.
value String The value of the preceding attribute field that must be matched exactly for the signal to be included in the list.
fieldName String The name of an attribute field. The following parameter can be a string value, which must be exactly equal for the signal to be included, or can be a regular expression. Any number of fieldName/value or fieldName/regExp pairs can be specified.
options int This is a set of flags that allows you to filter the list to include/exclude various categories of signals. This argument can be any OR of the following values:
  • 1 OPTION_SELECTED_ONLY
  • 512 OPTION_IGNORE_MODE
  • 2048 OPTION_INCLUDE_BUSSES
If this parameter is not given, you will get all non-pseudo-signals in the given circuit.

Returns:

Returns an SPArray object containing a list of all signals(DWSignal) specified by the option parameters.

Remarks:

Returns an array with one element for each signal requested. All signals on all pages of this circuit are included.

If no parameters are specified, you will get a list of all the signals on all pages of the given circuit.

A variety of different combinations of parameters can be passed, and the meaning of each is determined by the data type of the parameter. If the first one or two parameters are integers, then they are interpreted as the options and scope parameters, respectively. Once any non-integer (normally a string) parameter is encountered, this is assumed to be an attribute value filter, as follows

Any remaining parameters are taken as attribute field name/value or field name/regular expression pairs. Any signals matching the given values or patterns will be included in the list.

Note that this array is not updated automatically. If you perform other operations that add or delete signals, this array will be invalid and should be retrieved again. This can cause the program to bomb if misused!

Example:

cct = currentCircuit();
sigs = cct.signals();     // All the non-pseudo-signals in the circuit
sigs = cct.signals("Voltage", "120", "Name", /V1.+/);    // All signals with Voltage field equal to "120" and Name matching the given expression
sigs = cct.signals(1);        // All selected signals in the circuit

Method: undo

Performs an undo operation, exactly as if the Undo menu command was selected by the user.

void undo();

Method: zap

Applies a zap (selective delete) operation, exactly as if the user had clicked the Zap cursor at the given position

void zap(posX, posY);

void zap(pageNum, posX, posY);

Parameters
Name Expected Type Description
pageNum int Page number for the operation to be applied to. If not specified, the current page is assumed
posY int Y position of the zap location in circuit coordinates
posX int X position of the zap location in circuit coordinates

Remarks: